0~+5W
Power tolerance
12 YEAR
Product Warranty
21.23%
Module Efficiency
QUALIFICATIONS & CERTIFICATES
IEC 61215,IEC 61730,IEC 62941:2019,CE, ISO 9001:2015,ISO 14001:2015, ISO 45001:2018
PRODUCT DETAILS
ELECTRICAL PERFORMANCE | ||||||||
Electrical parameters at Standard Test Conditions(STC) | ||||||||
Module type | YCxxxPSF66M10/2(xxx=Pmax) | |||||||
Power output | Pmax | W | 480 | 485 | 490 | 495 | 500 | 505 |
Power output tolerances | △Pmax | W | 0/+5 | |||||
Module efficiency | ηm | % | 20.18 | 20.39 | 20.60 | 20.81 | 21.02 | 21.23 |
Voltage at Pmax | Vmpp | V | 37.68 | 37.84 | 37.99 | 38.14 | 38.29 | 38.44 |
Current at Pmax | Impp | A | 12.74 | 12.82 | 12.90 | 12.98 | 13.06 | 13.14 |
Open-circuit voltage | Voc | V | 44.91 | 45.04 | 45.18 | 45.31 | 45.45 | 45.58 |
Short-circuit current | Isc | A | 13.66 | 13.74 | 13.82 | 13.90 | 13.98 | 14.06 |
STC: 1000W/m2 irradiance, 25°C module temperature, AM1.5g spectrum according to EN 60904-3. | ||||||||
Average relative efficiency reduction of 3.3% at 200W/m2 according to EN 60904-1. | ||||||||
Max test power tolerance ± 3% |
Electrical parameters a t Nominal Operating Cell Temperature (NOCT) | ||||||||
Power output | Pmax | W | 365.22 | 369.07 | 372.85 | 376.64 | 380.45 | 384.28 |
Voltage at Pmax | Vmpp | V | 35.93 | 36.09 | 36.23 | 36.37 | 36.52 | 36.66 |
Current at Pmax | Impp | A | 10.16 | 10.23 | 10.29 | 10.35 | 10.42 | 10.48 |
Open-circuit voltage | Voc | V | 42.69 | 42.82 | 42.95 | 43.07 | 43.21 | 43.33 |
Short-circuit current | Isc | A | 11.00 | 11.07 | 11.13 | 11.20 | 11.26 | 11.33 |
NOCT:open-circuit module operation temperature at 800W/m2 irradiance, 20°C ambient temperature, 1m/s wind speed. |
Higher Durability
The multi-busbar design can decrease the risk of the cell micro- cracks and fingers broken.
High Power Density
High conversion efficiency and more power output per square meter,by lower series resistance and improved light harvesting.
Half-cell Design
Less energy loss cased by shading due to new cell string layout and split J-box, and lower cell connection power loss due to half-cell design.
Power guarantee
First year attenuation≦2%,2-25 year anual attenuation≦0.55%
Large size cell
The large cell design effectively increases module peak power and effectively reduces BOS costs, thereby reducing system costs.
About YC Solar
Yingchen Technology:
E-mail: sales@ycsolar.com
Tel.: +86 400 666 7111
Address: Changgucheng Industrial Park, Tang County, Baoding City, Hebei Province
Hotline: 0312-7510213
Address: No. 56 Hengyuan West Road, National High tech Zone, Baoding City, China Room 1606, B-3 Office Building, Beibu Gulf Science and Technology Park Headquarters Base